X-ray single crystal diffraction (SC - XRD)

SC - XRD detector

The ideal detector must be accurate records each photon diffraction.Our III and PHOTON II by PHOTON detector sensitivity, speed, dynamic range, the perfect combination of resolution and the detector size.

Application crystallography detector requires sensitivity, speed, dynamic range, resolution and unique combination of detector size.In company, we don't believe a size suitable for all applications, so the PHOTON III series provide different size of the detector.III and PHOTON II by PHOTON detector series full use of the advantages of high intensity of X-ray source.

The D8 QUEST ECO,The D8 QUESTandThe D8 VENTURECan be equipped with the innovative detector.All of our X-ray single crystal diffraction detector using our unique air cooling design, provides a great convenience and reliability, and have 3 years warranty.

On the flip chart.The development of X-ray detector

PHOTON 7, 14 and PHOTON III III by PHOTON III, 28

New PHOTON Ⅲ series brings us to the first at the same time support the pixel array detector, the PHOTON counting and integral optimal sensitivity and dynamic range.Due to no gap, no electric charge sharing, PHOTON III detector can realize the best laboratory crystallography research data quality.

Each probe the effective area of customized according to your lab using demand, to bring the best results.

  • The space domain of single photon counting
  • The effective area of 200 x 140 mm2No gap,
  • No count rate saturation, zero count losses
  • Any household laboratory detector of high frame rate
  • Eliminates the problems of the current mixed pixel array detector (HPAD) charge sharing noise.
  • Wide energy range with excellent sensitivity (alpha to Cu K K In alpha radiation)
  • Ignore the poor, even under the high Angle of incidence, the diffraction point remains in its true shape
  • No dead zone of time the shutter data collection
The photon counting and integral detection mode

III - mixed mode X-ray PHOTON detection

For best crystal structure need to be published X-ray detector has a high signal-to-noise ratio and the strength of the counting accuracy.

PHOTON III perfectly meet these requirements, provide hybrid model testing for the first time.Mixed mode detection combined with photon counting and integral at the same time, the strong diffraction and the weak diffraction signal can provide the best quality of the data.Traditional photon counting detectors, such as: HPC or HPAD, for strong diffraction, narrow, linear dynamic range and restricted by counting rate, greatly reduces the data quality.

PHOTON mixed mode III probes eliminates all detector noise, can achieve the highest degree of linearity, with the most challenging samples can also provide high quality data.

PHOTON III, there are three kinds of different size, because in the brook, we don't believe a single size can be suitable for all applications.The probe effective area according to the custom demand, ensure to provide the best performance.

  • PHOTON III 7: effective area of 70 x 100 mm2, the performance is better than that of most other systems.
  • PHOTON III 14: the effective area of 140 x 100 mm2That is the best solution for high-end crystallography solutions
  • PHOTON III 28: effective area of 140 x 200 mm2, no gap, maximize the photon counting pixels in indoor laboratory array detector.

7 and PHOTON II by PHOTON II 14

There are two kinds of PHOTON detector II size to choose from.The PHOTON II 7 is the effective area of 7 x 10 cm214 for the single chip, and PHOTON II 10 x 14 cm2.The D8 QUEST ECO,The D8 QUESTandThe D8 VENTUREMake full use of the detector.Our new series adopted by PHOTON III originally synchrotron and XFEL beam line for high-end technology principle of development, will introduce a hybrid model testing our indoor single crystal X-ray diffraction (XRD) solution.

  • Up to 10 x 14 cm2The large single effective area
  • Quantum limit sensitivity
  • Any indoor laboratory detector of high frame rate
  • Eliminates the problems of the current mixed pixel array detector (HPAD) charge sharing noise.
  • In the wide energy range have excellent sensitivity (alpha to Cu K K In alpha radiation)
  • Ignore the poor, that is, even under the high Angle of incidence, the diffraction point remains in its true shape
  • No dead zone of time the shutter data collection

resources

Service and support

We offer:

  • Professional senior technical personnel to do fault professional technical support, isolation and solve the problem of hardware and software
  • Network remote service, providing diagnosis and application support
  • Fusion reality support - virtual engineers in your side,video)
  • According to your request to schedule maintenance
  • Customer site maintenance, maintenance services
  • Spare parts delivery will be within one working day/the world needs a few working days to complete
  • Installation qualification and operational qualification/performance verification of compliance services
  • Site planning and relocation
  • Find nextA training course

Check out ourSupport site:

  • Software updates
  • Product manuals and installation guide
  • Training video