Small Angle X-ray scattering (SAXS)

The N8 HORIZON

Special small Angle X-ray scattering (SAXS) systems, compact appearance, suitable for high-end research and multi-user facilities

Help you to better explore nanometer world

SAXS WAXS -- GISAXS

Bright spot

SCATEX
No scattering pinhole
The composition of these unique pinhole and design, can produce the most clean high strength X-ray beam, used to detect the minimum Angle, and almost no background scattering.
90 °
The vertical direction of instrument
Unique innovation will rotate 90 ° beam path, will be able to reduce the laboratory area, and USES the level of the sample installation, so the gravity actually is good for you!
150 cm squared
Using VANTEC - 500 of 2 d large effective area
Taking advantage of the full view of the wide, shooting only once and can get all the isotropic or anisotropic scattering signal.
The N8 HORIZON sample room display for easy operation

Our N8 HORIZON small Angle X-ray scattering and wide Angle X-ray scattering (SAXS - WAXS) system is based on the principles of DAVINCI design development: the best analysis method and the most advanced technology, and put them with the combination of ease of use and safety to the extreme, provides the ideal solution for all applications.Support mirror adjustment of circular aperture collimator, general ergonomics sample room and large 2 d detector, is allowing you to complete any key components of SAXS experiments.Us the latest progress in optical technology, greatly reducing the traditionally longer main beam path, and equipment design for our unique vertical and horizontal sample installation paved the way.

The characteristics of

The main features

The N8 HORIZON characteristics

Brooke proprietary vertical light path

Compared with the traditional system of SAXS, brooke N8 HORIZON is most prominent a feature lies in our unique innovation vertical instrument Settings.This simple rotation has two advantages: first, in terms of exiguous lab, there is no other performance can match system have a so small area.Second, gravity has given you the advantage.You will be able to easily install samples in the horizontal direction, without the need for auxiliary tool for fixed.In the process of measurement, the sample will never deviate from the X-ray beam.

The N8 HORIZON characteristics

I (including micro JiaoYuan S

This unique X-ray source without water, can provide very stable high strength point focusing X-ray beam.Thanks to its rugged design, the gamma ray source with 3 years warranty.I (including S contains MONTEL integration, advanced 2 d beam plastic optical device, can achieve the highest intensity on the sample.The multilayer reflector design side by side can capture gamma ray source sent out large solid Angle x rays, and effectively in the highly parallel monochromatic beam redirect.

The N8 HORIZON characteristics

VANTEC - 5002 - d detector

Using MikrogapTMTechnology VANTEC - 500-2 - D detector can satisfy special SAXS system all the ideal requirements.First of all, no gas, water or routine maintenance, you also need not worry about radiation damage or movement, therefore, the probe is very strong and easy to use.Large effective area (14 x 14 cm2) which can realize large Angle, at the same time bring full field of vision.Very low background and high count rate, the biggest can achieve good dynamic range, and is very sensitive to the sample of weak scattering.Good spatial resolution, can solve the problem of small spacing scattering.At present, there is no other detector can provide this kind of ideal for the application of the function of the combination.

application

Critical applications

The N8 HORIZON application range

Small Angle X-ray scattering (SAXS)

Small Angle X-ray scattering (SAXS) is embedded into the phenomenon caused by different electron density of particles in the matrix.If particle size between 1 nm - 200 nm, the scattering Angle in the range of 0 ° to 5 °, depending on the use of X-ray wavelength.The smaller the particle, the greater the scattering Angle.

In any medium, any particle arrangement showed the difference of electron density, in the SAXS experiments, this results in a specific pattern.In addition to the particle size, SAXS can also identify the shape, distance and 2 d figure size distribution.Particles can be dissolved in the tissue of large molecules, metal deposition, biological mineral particles and surfactant micelle.

The N8 HORIZON application range

Swept into the small Angle X-ray scattering (GI - SAXS)

For detection of surface and subsurface structure details, we will with grazing incidence geometry measurement of the sample.Incident Angle is close to the so-called total reflection critical Angle, usually between 0.1 ° and 0.7 °.In swept into the small Angle X-ray scattering (GISAXS) experiment, we can through the 2 d detector, collect scattered in non coplanar direction of scattering intensity data.

With special electric tilt function of GI - SAXS sample machine is mainly used to aim the sample beam.

The N8 HORIZON application range

Wide Angle X-ray scattering (WAXS)

Compared with the SAXS, wide Angle X-ray scattering (WAXS) identification is the Angstrom level structure, is usually a crystal structure of planar spacing.WAXS is typically used for analysis of Prague, X-ray diffraction (XRD), which helps confirm crystal structure, crystallinity, crystallite size and phase composition (ID).Just put the second detectors in a more close to the location of the sample, can be in WAXS data collected at the same time, obtain SAXS data.

Technical parameters

The N8 HORIZON specifications

The characteristics of specifications

advantage

Overall dimensions

(h x w x d)

202 x 75 x 160 cm

79.5 x 29.5 x 63.0 inches

Compact design, without a single cooler, therefore in the laboratory area is very small

I (including micro JiaoYuan S

Air cooling, high strength, microfocus X-ray source

Low power consumption (30 w)

Standard 3 years warranty

No cold water machine

High power density will increase strength

Integrated Montel mirror which can realize the ideal beam adjustment

SCATEX pinhole

The ideal circular beam shape, parasitic background scattering is negligible

No parasitic aperture edge scattering

Higher resolution/higher flux

A more compact collimating light path, which can realize the vertical light path

Sample room

Large sample room with electric XY samples, used in general, standards, and the third party sample localization, mapping, and accommodate the sample machine

X: the range of 80 mm;Y: the range of 115 mm

Electric reference sample wheel

Can run in a vacuum, in order to reduce air scattering

Optional electric GI - SAXS and environmental samples

VANTEC - 5002 - d detector

Large effective area, low background, high sensitive 2 d detector

Large effective area (> 150 cm squared), is used to view all the SAXS scattering image

Very low background, therefore, is very sensitive

Better spatial resolution pixels (68 microns)

Free maintenance (without water/air, or to the main beam or moving sensitive detector under bias)

webinar

For more information

support

Service and support

We offer:

  • Professional senior technical personnel to do fault professional technical support, isolation and solve the problem of hardware and software
  • Network remote service, providing diagnosis and application support
  • Fusion reality support - virtual engineers in your side,video)
  • According to your request to schedule maintenance
  • Customer site maintenance, maintenance services
  • Spare parts delivery will be within one working day/the world needs a few working days to complete
  • Installation qualification and operational qualification/performance verification of compliance services
  • Site planning and relocation
  • Find nextA training course

Check out ourSupport site:

  • Software updates
  • Product manuals and installation guide
  • Training video

Need to register.