X-ray diffraction (XRD)

The D8 ADVANCE series

D8 ADVANCE diffraction series in a very efficient machine cabinets to provide you with a versatile platform: from no peripherals water-cooled D8 ADVANCE ECO to have the latest X-ray diffraction component D8 ADVANCE Plus.This series of products all adopt the same user friendly enclosure, and proven D8 goniometer.

D8 ADVANCE series is a series of used for X-ray diffraction and scattering analysis of hardware and software solutions, including phase identification, quantitative analysis, microstructure and crystal structure analysis, residual stress and texture research, X-ray reflection method, small Angle X-ray scattering and diffraction analysis of distribution function and the micro area.

No matter what the application, DIFFRAC. DAVINCI will guide the user to select the best instrument configuration.The DIFFRAC. The SUITE software package can be through the analysis of streamline method formulation and execution, for the novice user guide, at the same time provide expert assistance in low-key manner.With the help of powerful analysis software, people who want to get the best results, just press the button, in-depth analysis of the results can be obtained.

D8 ADVANCE series including ECO, ADVANCE and PLUS version, respectively for the best economical efficiency and optimal powder diffraction data quality and the most abundant materials research ability has been optimized.

Bright spot

The D8 ADVANCE series features

Safety shell

D8 ADVANCE shell to in smaller area, with the largest human body engineering and security advantages.The LED X-ray light and interactive screen buttons, can accurately display the current state of equipment, for your view.Internal use adjustable light LED lighting.In the shell internal cable management, structure of removable maze, ease of wiring.Use standard 19 inch rack equipment base, auxiliary controller can be installed temperature control samples.

Excellent safety and quality: the D8 ADVANCE in full compliance with all current eu directives, therefore the series in the X-ray security, machine safety, electrical safety and electromagnetic compatibility, hit a X ray analysis equipment of the world's highest standards, and provide guarantee for this.

The D8 ADVANCE series features

The D8 goniometer

  • Through the instrument performance verification and the latest NIST corundum provide the prototype SRM 1976 collimation
  • Goniometer using solid and maintenance-free design, guarantee for the performance of the whole life cycle
  • Applicable to a regulated industry, such as the pharmaceutical industry's IQ/OQ program
The D8 ADVANCE series features

DAVINCI design

DAVINCI. The DESIGN is brooke's pioneering DESIGN of diffraction instrument, which can realize the true sense of "plug and play", in the face of changing demand, multi-user environment and high-end research, it will be your ideal choice.With the aid of DAVINCI design, you will be able to easily switch including X ray tube, optical device, the sample stage and detector, optical path components, without having to aim at.By identifying all the components, you can also realize real-time adjustment and configuration validation.DIFFRAC. DAVINCI software plug-ins is a unique virtual goniometer software solution, it can display all of the light path components of the real goniometer and their status, and to report any configuration of conflict.

With DAVINCI design blessing, D8 ADVANCE became the general system in the true sense, whether current or any future application of X ray diffraction and scattering it has unparalleled ability to adapt.

With DAVINCI designed D8 ADVANCE: the operation is easy, intuitive, clear and support failure protection, suitable for any user (including the novice and expert).

Set the standard

The D8 ADVANCE series standard

For you make compliance laboratory solution: GLP and 21 CFR Part11

Brooke attaches great importance to your compliance obligations.

Brooke AXS provide software and hardware, it is according to the ISO9001 certification, the product development process (based on cGAMP), using a formal design process and product development life cycle development.Written standards include coding standard, configuration management, qualification of programmers, software version control, maintenance, software/hardware of formal testing, incident reporting and tracking, and disaster recovery, etc.

Brooke AXS also provides you with tools and professional knowledge, designed to help you meet § 21 CFR Part 11 B11.10 a regulation, system verification equipment qualification (EQ, IQ, OQ and PQ) requirements.

The D8 ADVANCE series standard

Instruments and data quality

Brooke has been providing customers with the best at the forefront of instrumentation and data quality.We offer unique collimation for D8 ADVANCE guarantee.Prior to the delivery and installation, each instrument must be through the international recognition, NIST standard reference material latest SRM1976 strict test.Within the scope of the whole Angle, the precision of each peak position must be equal to or better than + / - 0.01 °.Also, on the relative strength of certified and instrument resolution (FWHM) for validation.Each instrument is always accompanied with the latest NIST SRM 1976, so that the follow-up operate at any time after the upgrade and maintenance validation (OQ) and performance verification (PQ).

We provide all the necessary procedures, even the GLP strictly, can also help you to easily meet their requirements.

The D8 ADVANCE series specifications

specifications

ECO

The D8 ADVANCE

Plus

High dimension (x width x deep)

1868 mm x 1300 mm x 1135 mm (73.5 "x 51.2" x 44.7 ")

Weight (without electronic options)

770 kg (1697 LBS)

The power supply

Single phase

Two phase or three phase

Two phase or three phase

Water cooled

internal

external

external

goniometer

The D8

Component identification

artificial

automatic

automatic

The generator power

1 kW

3 kW

3 kW

compliance

In accordance with cGAMP / 21 CFR Part11

Electromagnetic compatibility/radiation safety

2014/30 / EU certification

Electrical safety

In accordance with 2014/35 / EU

Machine safety

In accordance with 2006/42 / EC