Based on unique D8 diffraction series platform D8 ADVANCE, is that all the X-ray powder diffraction and scattering ideal, such as:
Due to have excellent ability to adapt, use only the D8 ADVANCE, you can measure for all types of samples: from liquid to powder, from film to a solid block.
Both novice users and expert users, can be simple and quick, don't go wrong for the configuration changes.This is achieved by brooke unique DAVINCI design: configuration instrument, free tools, free collimation, at the same time also is supported by the automated real-time component identification and verification.
Not only such, brooke exclusive collimation based on NIST prototype corundum (SRM1976) guarantee.At present, in terms of peak position, the intensity and resolution, there is no other powder diffractometer accuracy than the D8 ADVANCE.
Metal industry
Building materials
The drug industry
Chemical products/paint
Energy storage/battery
Brooke patented TWIN - TWIN optical path design greatly simplifies the D8 ADVANCE operation and make it suitable for a variety of applications and the sample type.For convenience of users, the system could be used in four different automatically switch between beam geometry.Without human intervention, the system in the Bragg - Brentano powder diffraction geometry and bad shape samples, coating and film parallel beam geometry, and switch between them, without human intervention, is in the environment and the environment including powder, blocks, fiber, sheet and film (amorphous, polycrystalline and extension), including the choice of all types of sample analysis.
Brooke's unique DBO function for X-ray diffraction data quality to establish a new important benchmark.Motor drive divergence slit、防散射屏和可变探测器窗口的自动同步功能,可为您提供无与伦比的数据质量——尤其是在低2Ɵ角度时。除此之外,LYNXEYE全系列探测器均支持DBO:SSD160-2,LYNXEYE-2和LYNXEYE XE-T。
LYNXEYE XE - T is LYNXEYE detector series flagship product.It is currently on the market only a 0 d, 1 d and 2 d data of energy dispersive detectors, applicable to all wavelengths (from Cr to Ag), with the highest count rate and the best angular resolution, is the ideal choice for all the X ray diffraction and scattering application.
LYNXEYE XE - T has a better than the 380 eV energy resolution, really good, is the best on the market performance of fluorescence filter detector system.With the help of it, you can under the zero strength loss to 100% by the iron of radiation excitation fluorescence filter, filter without metal, so the data will not exist artifacts, such as residual K to decide and absorption edge.Similarly, also need not use to eliminate the intensity of the secondary monochromator.
Brooke provide unique LYNXEYE XE guarantee: -t detector on delivery to ensure no bad way!
DAVINCI design
Dynamic beam optimization (DBO)
LYNXEYE XE - T
For any partial or light path with TWIN light path
EIGER2 R detector
Make compliance laboratory solution for you
Equipment quality and data quality
X-ray powder diffraction (XRPD) technology is one of the most important material characterization tool.Powder diffraction figure a lot of information, directly from the phase arrangement of atoms.In the D8 ADVANCE and DIFFRAC SUITE software support, you will be able to implement common simply XRPD method:
The distribution function (PDF) is a kind of analysis technology, which is based on Bragg and diffuse scattering (" total scattering "), provide structure information of disordered materials.Among them, you can through the Bragg diffraction peak, average crystal structure of materials information (that is, the long range order), through the diffuse scattering, characterization of its local structure (i.e., short-range order).
On analysis of speed, data quality and amorphous, weak crystal type, nanocrystalline or nano structure materials in terms of the results of the analysis, the D8 ADVANCE and TOPAS software represents the best performance of PDF analytical solution on the market:
Thin film and coating analysis using the principle of the same as the XRPD, but further provides the Angle of beam adjustment and control function.Typical examples include, but are not limited to phase identification, crystal quality, residual stress, texture, thickness and composition and the strain analysis.The analysis of thin film and coating, of thickness between the nm and including m analyses characteristics of layered materials (from amorphous and polycrystalline coatings to epitaxial film).The D8 ADVANCE and DIFFRAC SUITE software high-quality film can make the following analysis:
Phase identification
Quantitative analysis of
Texture analysis
X-ray reflection method (XRR)
Small Angle X-ray scattering (SAXS)
function |
specifications |
advantage |
For any partial or light path and TWIN light path |
Software switch button: Motor drive divergence slit geometry (BB) High strength Ka1, two parallel beam High resolution Ka1 parallel beam Patents: US10429326, US6665372, US7983389 |
Can be in as many as six different automatic electric switch between beam geometry, without human intervention Is ideal for all types of sample analysis, including powder, block material, fiber, sheet and film (amorphous, polycrystalline and extension) |
Dynamic beam optimization |
Dynamic synchronous: Motor drive divergence slit Motor drive the scattering screen Variable detector window Scope: 2 Ɵ Angle is less than 1 degree to > is greater than 150 degrees |
Data is hardly affected by air, instrument, and the scattering of plane Greatly improving the detection limit, the quantitative analysis of a small amount of crystalline and amorphous phase In smaller 2 theta Angle, has the incomparable performance, can be on clay, drugs, zeolite and porous materials and other materials for accurate research |
LYNXEYE XE - T |
Energy resolution: < 380 eV @ 8 KeV Test mode: 0 d, 1 d and 2 d Wavelength: Cr, Co, Cu, Mo and Ag Patents: EP1647840, EP1510811, US20200033275 |
To decide without K with filter and secondary monochromator Iron radiation can be 100% filter fluorescence 450 times faster than conventional detector system BRAGG 2 d pattern: use the divergence of the primary data collected 2 d wiring harness Unique detector guarantee: when delivery is not bad |
EIGER2 R |
Dectris company development based on hybrid photon counting technology of a new generation of detectors, support for multiple model (0 d / 1 d / 2 d) |
In continuous scanning step scanning, and seamless integration in the advanced scanning mode 0 d, 1 d and 2 d test Ergonomic from probe rotating function, can optimize the gamma or 2 Ɵ Angle range Use full detector, free tools panoramic view of the diffraction beam optical systems Continuous variable detector position to balance the Angle range and resolution |
Rotating light tube |
Online focal spot and point between focal spot applications quickly and easily for free on the switch |
Don't need to disconnect cables or pipes, without having to remove the pipe DAVINCI design: the automatic detection and configuration focusing direction |
Automatic sampler |
FLIPSTICK: nine samples AUTOCHANGER: 90 as a sample |
Run in the reflection and transmission geometry |
The D8 goniometer |
With independent double circle of step motor and optical encoder goniometer |
Brooke unique collimating guarantee, ensure the accuracy and precision of unparalleled Absolutely free maintenance drive/gear, lubrication for life |
The environmental conditions |
Temperature: from 85 k to 2500 k ~ ~ Pressure: 10 - ⁴ mbar to 100 bar Humidity: 5% to 95% |
In the environment and the environmental conditions were studied The DIFFRAC designed to help you easily replace the sample units |
Bruker XRD solution contains a series of high-performance components to meet the demand of analysis.Modular design is the key to make the best instrument.
All kinds of components are brooke component part of the core competitiveness, they are made from brooke AXS development or, or by close cooperation with the third party suppliers.
Brooke XRD components can be used to upgrade the existing X-ray system, is used to improve its performance.
DIFFRAC. SUITE ™ brought rich software modules, allowing you to easily implement X-ray powder diffraction data collection and evaluation.Based on the Microsoft.net technology, DIFFRAC. Offers all the advantages of the technology of modern software SUITE, in order to realize the stability, the greatest of ease of use and connected to the Internet.
Fully customizable user interface is the feature of plug-in framework, provides a general appearance, feelings and actions.All the measurement and evaluation software module can run as a standalone application, also can be integrated to DIFFRAC. The SUITE of plug-in framework.Unlimited Internet access and control allows customers to network within any number of D2 PHASER, D8 ADVANCE, D8 DISCOVER and D8 ENDEAVOR diffractometer.
Measuring software:
WIZARD - method of planning
COMMANDER - method and direct measurement
TOOLS - instrument control tool entry:
Powder diffraction software:
DQUANT - quantitative analysis
EVA - phase identification and quantitative analysis
TOPAS - peak type analysis, quantitative analysis and structure analysis
Materials research software:
SAXS - small Angle X ray scattering software
XRR, comprehensive analysis of the X-ray reflection
TEXTURE - full of TEXTURE analysis meet the ease of use
Residual stresses LEPTOS - film analysis/research
We offer:
Check out ourSupport site:
Need to register.