X-ray diffraction (XRD)

DIFFRAC. EVA

The software can be used to analyze the two kinds of X-ray diffraction data, including data view, data deducted, phase qualitative and quantitative analysis, statistical analysis and so on.

Common data analysis

Conventional data and cutting-edge research

Bright spot

X-ray diffraction (XRD) workers "Swiss army knife"

DIFFRAC. EVA software can quickly analyze the two kinds of diffraction data.It is suitable for brooke all kinds of detectors and XRD scan type of data.EVA functions including data to deduct, basic data analysis and reporting, detailed diffraction peak qualitative and quantitative analysis, phase, and calculation of the degree of crystallinity and crystal size.

EVA can be combined with all the relevant database for phase analysis and qualitative analysis, also can use crystal structure and based on the chemical composition of XRF chemical analysis to get the reliable supplementary information.

And DIFFRAC. EVA also supports from today's fast detector effective evaluation to the big data, support the use of in situ environment, support high flux screening or spatial resolution measurements.The software not only provide a specific chart type, also provides advanced chemical measurement tools, so that through the cluster analysis and pattern matching identification and quantitative crystalline and amorphous forms.

It fully supports not only the conventional file-based analysis task, still can combine DIFFRAC. SUITE database daily analysis tasks, even in chapter 21 CFR part 11 of the regulations required, in a controlled environment for the pharmaceutical industry.Finally, DIFFRAC. EVA can be directly in the EVA, or use the DIFFRAC. SUITE results database manager and instrument, and compiled can graphics and user-defined report.

The characteristics of

Deduction, visualization and data operation

EVA is the preferred software is used for preliminary understanding.Streamline captured by stable probe the data in one or more of the picture, or will come from the two-dimensional scanning detector pixels to translate into conventional one-dimensional XRD data, is a very important step.EVA can provide perfect for further analysis of the one dimensional data of the tool.They both conventional signal processing and scanning operation, also include the focus on a single peak and complete scanning more advanced technologies.

Big data visualization and feature extraction

EVA in cluster analysis for a deeper understanding and intuitively display large X-ray data set.

Clustering analysis tools adapted from famous Polysnap software.It can help identify the known and unknown samples, analysis of mixture and outliers, and help to control the quality.It can be used for high-throughput screening, can also be used to analyze the environmental conditions of the data.

DIFFRAC. EVA, clustering analysis, three dimensional MMDS view

Measuring multidimensional scaling is a 3 d graphics said in cluster analysis method.EVA also provide PCA and up to six dimension chart, used to achieve more information visualization.

Large data sets and complementary information

Multiple scan reader can quickly load hundreds of scanning, and in the form of two-dimensional simply summarized the scan data.It's so easy to find outliers in conventional quality control measure, and from the reciprocal space figure or a series of variable temperature conditions or run measuring extract worthy of detailed study of a particular scan.

Added scanning information, such as measuring position, temperature, humidity, charge state, even a single peak intensity or the number of amorphous background, etc. - can display in the side view.Also, this information can help to find out for further study of phase transformation, phase decomposition or formation of the scan.

BRAGG2D

Using Bragg - Brentano geometric large beam footprint and high resolution, combined with using LYNXEYE detector series asymmetric one-dimensional detection methods, can be in a simple way to monitor the sample form (for example, because the grain size and structure of uneven, or because the grain size in the sample stage arrangement and form of preferred orientation of formation of the spot defects).DIFFRAC. EVA can be used to make these data visualization, and select a single scan needs further detailed research.

Phase analysis

Since its first release, retrieval of EVA/matching module is often considered the most reliable and the most accurate phase identification tool.And, in an international match/EVA has achieved the best results in round robin (Le Meins et al., 2002,www.cristal.org/smrr).Since then, EVA has experienced many times to improve again, making it more superior than conventional phase analysis software).

  • To have recognition phase scanning curves are highly complex residual peak retrieval function greatly improve the analysis of a small amount of phase.
  • Due to the lower limit detection limit (LLoD) is greatly reduced, support variable count time (VCT) and dynamic light beam optimization (DBO) data, in order to realize the highly accurate analysis of the trace phase.
  • At the same time in the multiple reference database retrieval, including ICDD PDF2 / PDF4 + / PDF4 minerals/PDF4 organic material database.
  • For grouping candidate phase, in order to deal with the increasing number of similar or nearly the same reference database entries.
  • Based on reference intensity ratio (rirs) values of the phase identification and accurate quantitative analysis phase.

advantage

The advantages of EVA

  • Gather all the best and the evaluation algorithm for data integration
  • Innovative design concept and operation, maximize the realization process simplified and flexible operation
  • Make full use of modern computer and operating system, such as multi-threaded, parallel, native support 64 - bit systems, etc
  • Real-time preview all analysis for visual inspection
  • Want to cancel an operation?No problem!EVA will allow you to cancel the operation and operation again
  • Highly flexible GUI can adapt to the available user hardware, best practices and requirements of various kinds of software modules
  • According to the user preferences custom window layout, the column configuration and Settings screen
  • With the DIFFRAC. Manager software SUITE measurements and results highly integrated
  • Detailed step-by-step tutorial for the use of EVA at first is very simple

application

On the analysis of the challenges you have?

The peak and phase detection

Analysis of a single peak linear or area data, to be used for quality control, monitoring the formation of grain type or change, or automatic determination of the peak/back than or signal-to-noise ratio.

Determination of crystallinity

Analysis of the crystallinity (or material ratio of the crystal and amorphous or nanocrystalline), requires careful analysis in extension of the interval of scanning range baseline and spectral peak.

Determination of grain size

Peak width is inversely proportional to the grain size.Scherrer formula can quantify the relationship.Can be based on the analysis of linear data or peak area to get DIFFRAC. The grain size of EVA.

Phase identification

DIFFRAC. EVA to efficiently match the XRD measurements and reference database provides a tool.This enables from more than 440000 kinds of inorganic compounds and more than 550000 known compounds, organic crystal quickly even automatically identify the compound in the mixture type.

Quantitative analysis of

Based on reference list format strength than half quantitative analysis, fast through the classic bar type drawing or complete spectra fitting quantitative composition of the mixture.Use of internal standard substance can also accounted for determination of the amorphous mixture compounds (wt %).

The crystal parameters

Can use the DIFFRAC. EVA software to optimize each crystal material geometric parameters of typical (abnormal behavior by considering the instruments and samples).

Clustering analysis

From up to six dimensions on similarity analysis and visualization, classification, automatically determine the amorphous and mixture analysis, put forward the following problems: I understand this material?It is similar to what kind of known materials?What are the typical representative in the material group?

Scan matching

By using correlation analysis and the measured reference scans, can identify and quantitatively in the database can't find the material.This applies not only to pure phase, and allowed to identify those itself is composed of multiple phase mixture.

The swing curve

Rocking curve is different by using two-dimensional detector series data obtained from the sample orientation, can be used to check about the quality of the single crystal or film for quick.

Technical parameters

DIFFRAC. The technical index of EVA

version

The latest software version for DIFFRAC. EVA V6, DIFFRAC. Part 11 V7

Database compatibility

Version 8 and two backwards compatible version, allowing the read/write access

compliance

CGxP / 21 CFR Part 11

The operating system

Windows 8, 32 bits
Windows 10 and 11, 64

support

Let your DIFFRAC. EVA keep the latest version

Free maintenance updates

Through the free DIFFRAC. EVA maintenance updates, your EVA version can be updated to the latest version.No matter what is your level of EVA licensing, you can via www.brukersupport.com as a free download the latest maintenance update.

Download the steps

  • In the "brooke customer support center (Bruker Customer Support) "registration
  • Click on the "software" button
  • Search for "DIFFRAC. EVA maintenance updates"
  • Download the update

Bug fix

By letting your DIFFRAC. EVA keep the latest version, no matter what permission level is, you have the right to use all the patches to the current version and to repair all previous releases.DIFFRAC. EVA is cumulative maintenance updates, thus it can be used for any previous versions.

What is the upgrade?

DIFFRAC. EVA maintenance update doesn't come with new features.If you want to use the function, introduced in the new version, you need to buy the latest DIFFRAC. EVA upgrade services.