Clean, fast and efficient combustion: ZoneProtect ™
HighSense ™ : used to detect the SO ₂ efficient ultraviolet absorption method
Induction furnace with high frequency (HF) and HighSense ™ detection technology of combustion analyzer G4 ICARUS Series 2, for fast and accurate analysis of the inorganic solid samples of carbon (C) sulfur content (S) set up the new post.
Because of the influence of carbon and sulfur on the properties of ceramic materials have, not only steel and iron the need for rapid and reliable analysis of carbon and sulfur, ferrous and non-ferrous metals and their alloys, ceramics, mineral, cement, limestone and many other inorganic solid also need to be fast and reliable analysis of the carbon and sulfur.
When you need to quickly get the results, and must first guarantee the accuracy of the results, and sample preparation requirements at least, the combustion analysis method in the analysis of light elements has the irreplaceable status.Especially for the elements of matrix of integration in the very difficult, it is difficult to measure them directly by spectroscopy and even impossible.For example, because is the entire sample is analyzed with capacity method, G4 ICARUS Series 2 can analyze the carbon in the form of graphite clusters is not evenly distributed in grey cast iron, and can provide accurate analysis result.
specifications | advantage | |||
The sample |
Inorganic matter, drying, any form or shape |
Highly flexible | ||
A typical sample |
Ferrous and non-ferrous metals and their alloys, ore, cement, limestone, glass, ceramics and soil | Different kinds of sample matrix | ||
The sample container |
Porcelain crucible (standard form) | To use the industry standard consumables, cheaper, more reliable supply | ||
The sample weight | 0.1-1 g (typical weight 0.5 g) | |||
Combustion furnace | High frequency induction furnace, power adjustable, ZoneProtect ™ | More efficient, more rapid combustion, the highest productivity | ||
The detector
sulfur |
With a reference channel double range NDIR detector With a reference channel HighSense ™ NDUV squared detector |
Reliable, free maintenance, no drift Unique super wide detection range, incomparable signal-to-noise ratio, no drift |
||
The carrier gas | Oxygen: 99.95% purity (when the detection of trace carbon must achieve 99.995% purity) Minimum pressure to 3.5 bar (50 psi) |
The standard gas purity can meet the requirements | ||
The compressed air | Minimum pressure 5 bar (72.5 psi), no oil, no water, no particulate matter | |||
speed Analysis time |
40 normal time (s) |
At the same time quick analysis | ||
A complete cycle time |
The < 1 min (typical) | High productivity and flux, waste disposal was transferred to the crucible | ||
Noise emissions | The < 50 db | Enjoy the quiet | ||
The calibration | Use solid standard for single point and multi-point standards | |||
The reagent |
|
|||
The power supply | 230 VAC (+ / - 10%);L1 N;50-60 Hz;16 A.2.7 kVA 208 VAC (+ / - 10%);L1 L2;50-60 Hz;16 A.2.7 kVA |
Industry standard power and current configuration | ||
*) can provide based on NDIR detector when necessary |