OPUS software vibration spectrum

OPUS: released the latest version

OPUS workbench

The latest version

OPUS workbench

8.7 is the latest version of OPUS software OPUS, OPUS is measurement, processing and evaluation of infrared, near infrared and Raman spectra of leading software, it can be compatible with Windows 10.OPUS is a true 64 - bit software, to provide the best performance under native 64 - bit operation.In addition to many further improvements, OPUS 8.7 features include exciting new microscope, and marks a new OPUS validator OVP - another important step of X, the program now also support INVENIO platform.

OPUS 8.7 new features include:

INVENIO OVP - X: the next generationOPUSThe validator OVP - X, allow better comfort, comprehensive and reliable instrument identification.

  • New advanced research and development function:

Multi spectral range - measured as a function of the machine OPUS, with intuitive user interface, including automatic spectrum merger and more options.

  • The new VCD and PM - IRRAS measurement functionThat directly support software control of a new generation of PEM (photoelastic modulator).
  • Python connectivity: in addition to the existing flexible access through HTTP interface OPUS, used for data processing and evaluation of Python scripts can now run and editing in the OPUS, including GUI integration and evaluation results stored in the OPUS data file.
  • A new infrared and Raman microscope(imaging and puzzle) :

- for high performance chemical image generated by k-means clustering are adaptive: independently determine the spectral variance, and defines data points assigned to the category, according to the results of chemical imaging.

- new particle analysis methods:For chemical analysis of particle image, provide the particle characteristics (quantity, size) and the overall statistics.

- used to identify the category of cluster ID function:Classification of sample composition of chemical identification, such as grain, layers of laminate, tablets and other heterogeneous material composition.

OPUS - TOUCH

The latest version

OPUS - TOUCH

Version 4 is the latest edition of the OPUS - TOUCH, OPUS - TOUCH is the first true TOUCH screen operation ir software.Touch screen for beginners FT - IR provides the highest accessibility, provides a complete instrument control experts, including the hardware and the system status monitoring.

New features include TOUCH 4:

  • Full compliance with FDA requirements of data integrityValidation of the environment: applicable to cGMP requirements.
  • The main screen and toolbar editor: adjust the touch of your own home screen, so that immediate access to the workflow and the function, and according to the needs of your custom workflow functions available
OPUS Homescreen Editor

  • Through the touch screen to send E-mail: used to share data and the results of another kind of connection option.
  • Automatically create PDF report: without any effort to record the results of the analysis.
  • A quick scan TRS method editorRapid scanning experiment: by touch screen Settings.
  • A new analysis of workflow, within the scope of the various spectral guide and automatic measurement, using specialized reflectance or transmittance accessories, such as A513, A519 and A510, or used for testing the emissivity.

BRAVO

The latest version

BRAVO

BRAVO version 2.1.12 is OPUS 8.7.31 support the latest version of the handheld Raman GUI software.Through reasonable working process (including various analysis tools and reporting options) intuitive guidance, at the same time just touch the icon on the touch screen.BRAVO专为在制药行业经验证的环境中运行而设计,并提供所有必需的功能,以满足开箱即用的监管要求。

BRAVO new handheld Raman features include:

  • Update OVP scheme, conform to the requirements of the latest pharmacopoeia(USP < 858 >, Ph. Eur. 2.2.48, JP, 2.26).

  • BRAVOGUIThe password change options, spectral range extended to 170 cm - 1, and further optimize the software performance.

ONET

The latest version

ONET

ONET 3.1 software is based on the browser's web interface (WebUI) access server applications, allowing anywhere in the world, set up, manage and control the FT - IR or FT - NIR instrument network.Local spectrometer measuring all data for centralized storage.In spite of this, all the data and the required documents are available locally, even temporarily disconnect network, also can analyze samples at any time.

New ONET 3.1 features include:

  • Brand new and modern Web user interface
  • ONET client with faster, more efficient communication

  • Through. CSV import distribution reference through easily. CSV import distribution reference easily

CMET

The latest version

CMET

CMET 3.1 is the latest version of the software process, it will be Bruker outstanding FT - process of NIR analyzer with the customer of the distributed control system (DCS).Command is transmitted from the DCS to CMET CMET in turn start the specific measure, and to transmit the data back to the DCS, so that visualization and archiving and process monitoring and optimization.CMET support a variety of standard communication protocols, such as Modbus, Profibus DP, 4-20 mA and OPC, ensure that the best connection.

New CMET 3.1 features include:

  • Online deviation, formulation (simplified batch processing), and controlCMETAs a service.
  • Support the launch head Q412 series and its additional monophyletic model.
  • With a new interface, log in function and the trend of database connection diagram.