The probe

SWB probe + mini WB90

Brooke's vertical ultra wide hole (SWB) magnet for 66 mm in diameter sample space.Therefore, it is one of the largest vertical brooke magnet system, room temperature to 154 mm in diameter.MiniSWB90 rf ultra wide hole probe study materials research and process parameters are optimized.

Brooke's vertical ultra wide hole (SWB) magnet for 66 mm in diameter sample space.Therefore, it is one of the largest vertical brooke magnet system, room temperature to 154 mm in diameter.MiniSWB90 rf ultra wide hole probe study materials research and process parameters are optimized.The system is equipped with combination of SWB gradient/filling system.Can choose to install additional WB filling system in the SWB gradient/filling system.All SB and WB gradient, filling and MR microscope, MR diffusion, solid and compatible, suitable for various purposes.SWB drive hardware needs from the standard spectrometer driver amplifier rack, provide the power of up to 200 A, 785 mT/m and create maximum gradient intensity.SWB system with 300 or 500 MHz configuration.

Characteristics of the

Ultra wide hole probe

The gradient strength up to 785 mT/m, water-cooled

Compatible with high resolution and solid application

Cover an area of an area small

Probe available:

  • 66 mm ID 1 h quadrilateral probe
  • 40 mm ID 1 h quadrilateral probe
  • 66 mm ID 1 h / 13 c and 1 h / 19 f probe
  • 40 mm ID 1 h / 13 c and 1 h / 19 f probe
  • All the other detectors should be required

Optional variable temperature control (compatible with BSVT, BCU)

application

MR operation microscope in the ultra wide hole system M 14
Ultra wide aperture spectrometer of the single-phase flow velocity measurement M 15

specifications

Mini WB57R/mini 0.75
Compatible with magnet systems Swb
hole Swb
1 h frequency range 300 or 500 MHz
The rf channel Two independent
requirements SWB imaging accessories
The gradient BGA9
The direction of Xyz
Each direction of the gradient intensity 785 mT/cm
ID/OD 57/72 of a millimeter
Rise time (5-95%), 0 to 60. A, 120 v < 100 mu s
cooling water
The biggest current has been tested 200 A
mobile yes
Replaceable rf coil
detection Monotonous, double or quadrangle
A typical nuclear 1 h, 2 h, 19, 13 c and 31 p f, 7 li, 19 f...
Standard sample temperature range 5 ~ 40 ° C
The sample diameter 40-66 - mm

accessories

  • Optional SB and WB gasket coil, used in the SWB magnets in standard SB/WB probe

support

Here, we should have standard brooke support hotline, etc

Contact experts

MR microscope and MR diffusion application team: micdiff@bruker.com