Join the AVANCE TRACK, let you moment of MRI in the most advanced level

MRI upgrade plan

Your research results depend on magnetic resonance imaging of the escalating.So you need a reliable nuclear magnetic resonance (NMR) imaging, can not only meet the daily use, but also to meet the needs of the future.Honour enjoy cutting-edge technology, let your instruments and your career to the next level, ensure that your equipment can meet the research needs in the future.The most important of all, to protect the precious investment, whenever a notable interest areas, you can fast one step.Upgrade your Bruker instrument instrument or other brands, keeping equipment, prolong service life

An overview of the

Your exclusive upgrade scheme

Instantly add AVANCE Track, simple and quick.Bruker现有用户可使用便捷通道,快速升级,而其他品牌(如 Agilent)MRI 仪器的用户也可通过特别程序满足需求。

Other brands instrument user

Other brand instruments if users want to upgrade, we will assign experienced engineers on-site check and analysis of the existing configuration of the instrument.Then according to these information, clear/transparent upgrade to meet the requirements of the user equipment.Users can also flexible definition to meet the requirements of scientific needs and budget AVANCE track elements.After users choose the right configuration, service engineers can implement upgrade, put the instrument to regain vitality, play unlimited potential.

Brooke existing users

Brooke existing users 360 ™ software can be upgraded to provide ParaVision AVANCE NEO electronics, make sure that always use the most advanced technology.According to the existing equipment configuration, providing personalized upgrade plan, including shimming, gradient, AVANCE NEO console to upgrade multiple components, such as simple and easy to help users with AVANCE NEO and ParaVision 360 ™, and realizes the transformation to the software and hardware platform for the future.

Bright spot

  • Innovative AVANCE NEO electronics and ParaVision 360 ™ software, rf coil with excellent technology, improve equipment performance
    • From the hardware setup, scan to quantify and data management, improve work efficiency
    • At any time to enjoy advanced achievements, obtain the Bruker scientific support, the most important thing is, can join the magnet or the whole machine maintenance plan, all-round protection equipment, ensure that the instrument is suitable for use in the future
    1. PET machine only
    2. BioSpec only 3 t and PET inline mri machine

    The technical details

    Improve performance

    A solid foundation

    • High performance gradient coil and shimming coil, and the AVANCE NEO electronics perfect combination, make the most solid foundation for magnetic resonance imaging
    • High power shimming amplifier, sharply reduce TrueFSIP shimming artifacts in a sequence of sensitive, at the same time improved the quality of EPI
    • Compared with superior high power gradient, suitable for conduction fMRI contour sequence or perform heart the first time tracer uptake
    • AVANCE NEO electronics gradient resolution can reach 1 mu s, real-time decision-making unparalleled speed
    • Flexible configuration of 24 transmission channel and 16 to receive channel, ensure the extension freely, to adapt to the future application

    The most comprehensive clinical front line product portfolio

    • Magnetic resonance imaging (fmri) low temperature probe can improve the SNR, 6 times can improve the measurement speed and/or resolution
    • Special coil, such as genetic coil ASL coil and light
    • Parallel transmitter coil, up to eight channels
    • Phased front, up to 16 channels
    • Whole series of classic room temperature for 1 h nuclear coil coil and X

    ParaVision 360 ™ advanced method

    • All of the usual spin, gradient spread spectrum method
    • All the standard, EPI and short echo imaging method, such as DTI - screw, UTE and T1 EPI, applicable to the diffusion and perfusion, fMRI, blood flow imaging and relaxation time measurement
    • Unique IntraGate based FLASH and UTE method, suitable for the gating wireless heart and respiratory system imaging
    • Fat chemical shift artifact correction RARE images
    Arterial spin labeling inspection guide, providers: e. Barbier, Hirschler, j. l. Warnking, Grenoble institute of neuroscience.Grenoble institute of neuroscience, Emmanuel Barbier participate in the development of the CASL workflow packages

    Simplify the work flow of and quickly

    Quick setup

    • Can be combined at the same time four rf coil, have the initiative to harmonic functions.
      Radio frequency (rf) coils, gradient coil and shimming coil automatic hardware identification, peak power limit is controlled by software

    Efficient scan

    • Optimization scheme and the scanner in the body, readily available, the first day to get the best results
    • As far as possible consistent with ASL inspection guidelines to keep data, greatly reduce deviation by the user
    • With the help of comprehensive assessment IntraGateUTE super-fast complete heart
    • ParaVision 360 software, simple operation, and with
    • Brooke opening sequence programming framework

    Dilated reconstruction and analysis

    • Fast 2 d and 3 d image registration post-processing, suitable for PET and/or MRI data, the fusion image, outline image analysis, histogram and ROI value updated in real time
    • Image time process analysis and multiparameter fitting, surface and volume, and image matching
    • Customized professional data report containing all of the scanning parameters
    • With functions of hierarchical ordering and free text retrieval functions of the database
    Thanks to UTE and radial read short echo time, under the condition of 9.4 T, compared the gating IntraGateUTE IntraGateFLASH reduced blood flow and the motion artifact in mice, even speed has no influence.Acquisition details: TE: 0.4/1.5 (IgUTE/ms IgFLASH), TR: 9 ms, resolution (98 x 98) including m squared, layer thickness: 800 (including m film frame: 14

    Free download AVANCE Track - MRI upgrade manual

    Sound investment

    For the future
    • A new generation of AVANCE NEO electronics, enjoy the software upgrade services, including method, sequence and module in the future
    • For PET/MR instrument

    Continued support

    • On-site training, internal training and webinars
    • Free email and service hotline

    Investment has a security

    • LabScape maintenance agreement and quality procedures
    • LabScape combo, covering all technical problems, can replace a full set of system
    Compared with the mouse coil at room temperature, using magnetic resonance imaging (fmri), low temperature probe, under the condition of 9.4 T, little mouse SNR average growth coefficient is 2.8.Collect details: FLASH, resolution (78 x 78 x 500) including m3, TR: 400 ms, TE: 3.8 ms, total length: 3 minutes and 24 seconds
    RARE water fat separation imaging, under the condition of the 7 T, the formation of fat chemical shift calibration image acquisition details: TE: 24 ms, TR: 350 ms, resolution (208 x 188) including m2, layer thickness: 1 mm, TA: > 1 m 7 s respiratory triggered on each floor

    LabScape

    Brooke BioSpin nuclear magnetic resonance (NMR) and preclinical imaging products, services and lifecycle support

    Brooke promises to provide clients with unparalleled throughout the buying cycle, from the initial consultation to the evaluation, installation, and service life of the instrument, it is LabScape always adhere to the service concept.

    LabScape Maintenance agreement (Maintenance Agreements), the optional services (On - site On - Demand) and laboratory improvement plan (Enhance Your Lab) modern Lab is dedicated to provide you with a new method of Maintenance and service.

    LabScape - Remote Monitoring